Kito

General: Loads (WLL – Proof Load – Breaking Force): according to EN 818-2 +25%.
Total ultimate elongation: 20% min; 25% min only for self coloured finishing.
Proof Load: Ratio of WLL to Proof Load to Breaking Force (Safety Factor): 1 : 2.5 : 4

  • Marking: According to standard, At least every 20th link, or at least one link per meter, is labeled with manufacturer, grade and traceability code.
  • Temperature range: -29-205°C (VIS 200) -40-380°C (VIS 400)
  • Finish: Blue painted (VIS 200) Green painted (VIS 400)
  • Standard: EN 818-2
  • Safety factor: 4:1
  • Grade: 10
Select a row from the table below, then click the add to quote button
Part Code Code Diameter
mm
WLL
ton
Breaking force (kN) Proof Load (kN) Nominal Pitch (p) (mm) Inside width w1 min (mm) Outside width w2 max (mm) Weight
kg/m
CAD
11.65DE01060DE0021 VIS200-6 6 1.4 56,5 35,3 18 7,8 22,2 0.83
11.65DE01080DE0035 VIS200-8 8 2.5 101 62,8 24 10,4 29,6 1.51
11.65DE01100DE0043 VIS200-10 10 4 157 98,2 30 13 37 2.3
11.65DE01130DE0053 VIS200-13 13 6.7 265 166 39 16,9 48,1 4
11.65DE01160DE0035 VIS200-16 16 10 402 251 48 20,8 59,2 6
11.65DE01190DE0006 VIS200-19 19 14 567 354 57 24,7 70,3 8.4
11.65DE01200DE0021 VIS200-20 20 16 628 393 60 26 74 8.9
11.65DE01220DE0014 VIS200-22 22 19 760 475 66 28,6 81,4 11.4
11.65DE01260DE0008 VIS200-26 26 26.5 1,060 664 78 33,8 96,2 16

Download CAD

Description

Get CAD
Download